OMD-Graviner MK 6

The Graviner Mk6 OMD is an analogue addressable oil mist detection system, capable of monitoring up to 64 detector heads fitted on up to 8 engines. This is achieved without sample pipes and with minimum cabling.

Model : Graviner Mk6

Click to Buy Now!
Category:

Description

The Graviner Mk6 OMD is an analogue addressable oil mist detection system, capable of monitoring up to 64 detector heads fitted on up to 8 engines. This is achieved without sample pipes and with minimum cabling. Each detector head monitors a single crankspace and is a stand-alone device. When assigned a unique address and supplied with 24V DC it gathers oil mist density data and converts it to a digital signal for transmission via the data cable to the control unit.

Specifications

Construction
Detector Black Zytel 70G30 Nylon 66
Junction Box Cast Aluminium Control
Unit Painted mild steel enclosure
Response time Less than 1.2 seconds for a 64 detector system
Sensitivity Detects average crankspace oil mist densities between 0.3mg/l and 1.3mg/l. Easily adjustable by customer to suit individual engine (lower explosion limit 30 – 50mg/l depending upon oil type). Detects variation of individual crankspace densities from the average of between 0.05mg/l and 0.5mg/l (simple adjustment by customer).
Operating Temperature Detector and Junction Box: 0 – 70°C (ambient and sample temperature) Control Unit: 0 – 55°C ambient
Strorage temperature -20°C to +60°C
System Protection Detector and Junction Box: Designed to meet IP65. Salt fog immune. Control Unit: Designed to meet IP32.
Operating Voltage 24V DC (+30%  -25%)
Power Consumption Detector: 116mA      Control Unit: 215mA
Protection By self re-settable fuse inside Control Unit; Junction Box 4.0 amp fuse
Insulation Flash tested to 2000V for 1 minute
Immunity to noise System tested to requirements of classification societies including:

– Radiated susceptibility to radiated noise

– Conducted susceptibility to electrical noise

– Short duration supply interruption

– 1kV high frequency transient voltages

System Outputs –       Fault alarm: 1 set volt-free change-over relay contacts. Relay normally energised when system is powered. De-energises for fault or test condition.

–       Main alarm: 1 set volt-free change-over relay contacts. Relay normally energised when system is powered. De-energises for alarm or test condition.

–       Engine shutdown: 8 sets of volt-free change-over relay contacts. Relays normally de-energised when system is powered. Energises for alarm or test condition.

Back-up Alarm 1 set per engine mounted junction box.
Alarm Ranges Average: 0.3mg/l to 1.3mg/l

Deviation: 0.05mg/l to 0.5mg/l

Back-up: 1.6mg/l fixed

Output relay contacts 30V 1A DC
System dimensions

(L x W x H)

Detector: 95 x 205 x 175

Junction Box: 318 x 186 x 90 (mm)

Control Unit: 500 x 313 x 118

(Bulkhead mounting)  619 x 369 x 118

(Panel mounting)

System weights (kg) Detector: 0.6

Junction Box: 2.7

Control Unit: 6.6

Reviews

There are no reviews yet.

Be the first to review “OMD-Graviner MK 6”

Your email address will not be published. Required fields are marked *