Description
A 15ppm Bilge Alarm is normally used in connection to a ship’s oil filtering equipment (also known as “bilge water separator”), monitoring the oil content of the separated/filtered water and stopping the discharge into the sea if the oil content exceeds 15ppm (parts per million). The 15 ppm bilge alarm type “BilgMon 488” is type approved for this purpose according to latest IMO Rules MEPC.107(49).
Furthermore the 15ppm bilge alarm can in principle be used as a simple oil content alarm for other applications where the water does not contain solids or other substances disturbing the operation.
Features
- Oil content range 0 – 30ppm (current output 0 20mA or 4 20mA)
- Approvals according to MEPC.107(49)
- Power supply 115/230 VAC or 24V AC/DC
- Measuring cell with wireless communication, easy to replace
- Automatic fresh water flushing
- User interface LCD display and keypad
- Data retrieval via LCD display or USB
- Supplied complete with 3 way flushing valve, piping set, connectors
Specifications
Versions | When ordering, specify high voltage (115/230V AC) or low voltage (24V AC/DC) version. |
Measurement | |
Oil range | 0 – 30 ppm
|
Resolution | 0.1 ppm |
Accuracy | According to IMO MEPC.107(49) |
Response time | < 3 sec |
Alarms | |
Alarm 1 (valve control) delay | 0-10 sec user adjustable |
Alarm 2 (annunciation) delay | 0-600 sec user adjustable |
Alarm points 1 and 2 | 1-15 ppm user adjustable |
Alarm hysteresis: | 0.5 ppm (below alarm point) |
Data storage and retrieval: | |
Calibration storage | Stored in sensor housing |
IMO required data | Stored in BilgMon488 main housing (sensor housing may be replaced with data remaining on board) |
IMO required data retrieval | Via LCD display or USB |
User interface | |
LCD display | 2×16 alphanumeric display |
Control | 4 button keypad |
Input/Output | |
Current output | 0 – 20 mA or 4 – 20 mA for 0 – 30 ppm |
Communications | USB serial communication (separate cable and software) |
Alarm outputs | 115/230 V AC model: 2 x relays (0.25A) 24 V AC/DC model: 2 x relays (1A) |
Clean water solenoid valve output | 115/230 V AC model: 1 x relay (0.5A, supply voltage) 24 V AC/DC model: 1 x relay (1A, supply voltage) |
Switch input | 1 x switch input for separator status |
System and supply | |
Supply, High voltage version | 1 A, 115 or 230 V AC, 50 – 60 Hz |
Supply, Low voltage version | 1.5 A, 24 V AC (50 – 60 Hz) or 24 V DC |
Power consumption electronics | 10 VA |
Power consumption solenoid | 18 VA |
Reviews