15 ppm Bilge Alarm – Bilgmon 488

A 15ppm Bilge Alarm is normally used in connection to a ship’s oil filtering equipment (also known as “bilge water separator”), monitoring the oil content of the separated/filtered water and stopping the discharge into the sea if the oil content exceeds 15ppm (parts per million).

Model : Bilgmon 488

Click to Buy Now!
Category:

Description

A 15ppm Bilge Alarm is normally used in connection to a ship’s oil filtering equipment (also known as “bilge water separator”), monitoring the oil content of the separated/filtered water and stopping the discharge into the sea if the oil content exceeds 15ppm (parts per million). The 15 ppm bilge alarm type “BilgMon 488” is type approved for this purpose according to latest IMO Rules MEPC.107(49).

Furthermore the 15ppm bilge alarm can in principle be used as a simple oil content alarm for other applications where the water does not contain solids or other substances disturbing the operation.

Features

  • Oil content range 0 – 30ppm (current output 0 20mA or 4 20mA)
  • Approvals according to MEPC.107(49)
  • Power supply 115/230 VAC or 24V AC/DC
  • Measuring cell with wireless communication, easy to replace
  • Automatic fresh water flushing
  • User interface LCD display and keypad
  • Data retrieval via LCD display or USB
  • Supplied complete with 3 way flushing valve, piping set, connectors

Specifications

Versions When ordering, specify high voltage (115/230V AC) or low voltage (24V AC/DC) version.
Measurement
Oil range 0 – 30 ppm

 

Resolution 0.1 ppm
Accuracy According to IMO MEPC.107(49)
Response time < 3 sec
Alarms
Alarm 1 (valve control)  delay 0-10 sec user adjustable
Alarm 2 (annunciation) delay 0-600 sec user adjustable
Alarm points 1 and 2 1-15 ppm user adjustable
Alarm hysteresis: 0.5 ppm (below alarm point)
Data storage and retrieval:
Calibration storage Stored in sensor housing
IMO required data Stored in BilgMon488 main housing   (sensor housing may be replaced with data   remaining on board)
IMO required data retrieval Via LCD display or USB
User interface
LCD display 2×16 alphanumeric display
Control 4 button keypad
Input/Output
Current output 0 – 20 mA or 4 – 20 mA for 0 – 30 ppm
Communications USB serial communication (separate cable   and software)
Alarm outputs 115/230 V AC model:  2 x relays (0.25A)   24 V AC/DC model: 2 x relays (1A)
Clean water solenoid valve output 115/230 V AC model: 1 x relay (0.5A, supply voltage)   24 V AC/DC model: 1 x relay (1A, supply voltage)
Switch input 1 x switch input for separator status
System and supply
Supply, High voltage version 1 A, 115 or 230 V AC, 50 – 60 Hz
Supply, Low voltage version 1.5 A, 24 V AC (50 – 60 Hz) or 24 V DC
Power consumption electronics 10 VA
Power consumption solenoid 18 VA

Reviews